GroMoPo Metadata for Afigya Sekyere South District model


Authors:
Owners: gromopo_admin
Type: Resource
Storage: The size of this resource is 1.5 KB
Created: Feb 08, 2023 at 9:14 p.m.
Last updated: Feb 08, 2023 at 9:15 p.m.
Citation: See how to cite this resource
Sharing Status: Public
Views: 715
Downloads: 220
+1 Votes: Be the first one to 
 this.
Comments: No comments (yet)

Abstract

A steady state groundwater flow model was calibrated to simulate the complex groundwater flow pattern in some crystalline aquifer systems in north-central Ghana. The objective was to develop the general geometry of the groundwater system and also estimate spatial variations in the hydraulic conductivity field as part of efforts to thoroughly investigate the general hydrogeology and groundwater conditions of aquifers in the area. The calibrated model was used in a limited fashion to simulate some scenarios of groundwater development in the terrain. The results suggest the dominance of local groundwater flow systems resulting from local variabilities in the hydraulic conductivity field and the topography. Estimated horizontal hydraulic conductivities range between 1.04 m/d and 15.25 m/d, although most of the areas consist of hydraulic conductivities in the range of 1.04 m/d and 5.5 m/d. Groundwater flow is apparently controlled by discrete entities with limited spatial interconnectivities. Recharge rates estimated at calibration range between 4.3% and 13% of the annual rainfall in the terrain. The analysis suggests that under the current recharge rates, the system can sustain increasing groundwater abstraction rates by up to 50% with minimal drawdown in the hydraulic head for the entire terrain. However, with decreasing groundwater recharge as would be expected in the wake of climate change/variability in the area, increased groundwater abstraction by up to 50% can lead to drastic drawdowns by more than 25% if recharge reduces by up to 50% of the current levels. This study strongly recommend the protection of some of the local groundwater recharge areas identified in this study and the promotion of local recharge through the development of dugouts and other conduits to encourage recharge. (C) 2015 Elsevier Ltd. All rights reserved.

Coverage

Spatial

Coordinate System/Geographic Projection:
WGS 84 EPSG:4326
Coordinate Units:
Decimal degrees
Place/Area Name:
Ghana
North Latitude
7.1000°
East Longitude
-1.4000°
South Latitude
6.8300°
West Longitude
-1.6000°
Leaflet Map data © OpenStreetMap contributors

Content

    No files to display.

Additional Metadata

How to Cite

GroMoPo, S. Ruzzante (2023). GroMoPo Metadata for Afigya Sekyere South District model, HydroShare, http://www.hydroshare.org/resource/828fce5371e0450fbce60b6302b54bc7

This resource is shared under the Creative Commons Attribution CC BY.

http://creativecommons.org/licenses/by/4.0/
CC-BY

Comments

There are currently no comments

New Comment

required